Component Tests and General Diagnostics
Component InspectionFLOOR SHIFT
Shift Lock Solenoid
^ Check operation by applying battery voltage to A/T device terminal 9 and ground to terminal 10.
CAUTION: Be sure to apply the voltage of the correct polarity to the respective terminals. Otherwise, the part may be damaged.
DETENTION SWITCH
For Key
^ Check continuity between terminals of the A/T device.
For Shift
^ Check continuity between terminals of the A/T device.
KEY LOCK SOLENOID
Key Lock
^ Check operation by applying battery voltage to key switch and key lock solenoid terminal 1 and ground to terminal 2.
CAUTION: Be careful not to cause burnout of the harness.
Key Unlock
^ Check operation by applying battery voltage to key switch and key lock solenoid.
CAUTION: Be careful not to cause burnout of the harness.
KEY SWITCH
^ Check continuity between terminals of the key switch and key lock solenoid.
STOP LAMP SWITCH
^ Check continuity between terminals of the stop lamp switch.
Check stop lamp switch after adjusting brake pedal.