Component Inspection (Shift Lock Relay)
SHIFT LOCK SYSTEM
Component Inspection (Shift Lock relay)
1.CHECK SHIFT LOCK RELAY
Apply voltage to terminals of shift lock relay connector to check the continuity.
CAUTION:
Connect the fuse between the terminals when applying the voltage.
Is the inspection result normal?
YES - INSPECTION END
NO - Replace shift lock relay.