Component Inspection
POWER SUPPLY AND GROUND CIRCUIT
POWER WINDOW MAIN SWITCH : Component Inspection
1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH
1. Check continuity between main power window and door lock/unlock switch terminals for front window RH.
2. Check continuity between main power window and door lock/unlock switch terminals for rear window LH.
3. Check continuity between main power window and door lock/unlock switch terminals for rear window RH.
Is the inspection result normal?
YES - Main power window and door lock/unlock switch is OK.
NO - Replace main power window and door lock/unlock switch. Power Window Main Switch.