Power and Ground Distribution: Testing and Inspection
POWER SUPPLY AND GROUND CIRCUIT
Diagnosis Procedure
Regarding Wiring Diagram information, [1][2]Electrical Diagrams.
1. CHECK FUSIBLE LINKS
Check that the following IPDM E/R fusible links are not blown.
Is the fusible link blown?
YES - Replace the blown fusible link after repairing the affected circuit.
NO - GO TO 2
2. CHECK BATTERY POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R.
3. Check voltage between IPDM E/R harness connectors and ground.
Is there voltage on all pins?
YES - GO TO 3
NO - Repair or replace harness.
3. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between IPDM E/R harness connectors and ground.
Does continuity exist?
YES - Inspection End.
NO - Repair or replace harness.