Control Unit: Service and Repair
DIFFERENTIAL LOCK CONTROL UNIT
Removal and Installation
REMOVAL
1. Disconnect the battery cable from the negative terminal.
2. Remove the instrument lower panel LH. Instrument Lower Panel LH.
3. Disconnect the differential lock control unit connector.
4. Remove the two bolts and remove the differential lock control unit.
INSTALLATION
Installation is in the reverse order of removal.
- When installing differential lock control unit, tighten bolts to the specified torque.
- After the installation, check DIFF LOCK indicator lamp. Precaution For Servicing Rear Final Drive.