Operation CHARM: Car repair manuals for everyone.

Removal And Installation




AIR CLEANER AND AIR DUCT

Removal and Installation


CAUTION:
Handle mass air flow sensor with care.
- Do not shock it.
- Do not disassemble it.
- Do not touch its sensor.
NOTE:
Add marks as necessary for easier installation.

REMOVAL

1.Remove engine room cover (if equipped).
2.Disconnect the harness connector from air cleaner case (upper).
3.Disconnect crankcase ventilation hose.
4.Remove the air duct and resonator assembly and air cleaner case (upper).
5.Remove air cleaner filter and air cleaner case (lower).

INSPECTION AFTER REMOVAL

Inspect air duct and resonator assembly for cracks or tears.
- Replace air duct and resonator assembly as necessary.

INSTALLATION

Installation is in the reverse order of removal.