None Of The Power Windows Can Be Operated Using Any Switch
NONE OF THE POWER WINDOWS CAN BE OPERATED USING ANY SWITCH
Diagnosis Procedure
1. CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit.
BCM.
Is the inspection result normal?
YES- GO TO 2
NO- Repair or replace the malfunctioning parts.
2. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH
Check main power window switch.
Component Inspection.
Is the inspection result normal?
YES- GO TO 3
NO- Replace main power window and door lock/unlock switch. Power Window Main Switch.
3. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH POWER SUPPLY AND
GROUND CIRCUIT
Check power window switch main power supply and ground circuit.
Component Function Check.
Is the inspection result normal?
YES- Check intermittent incident. Intermittent Incident.
NO- Repair or replace the malfunctioning parts.