POWER SUPPLY AND GROUND CIRCUIT
Diagnosis Procedure
1. CHECK FUSIBLE LINK
Check that the following IPDM E/R fusible link is not blown.
Is the fusible link fusing?
YES- Replace the blown fusible link after repairing the affected circuit if a fusible link is blown.
NO- GO TO 2.
2. CHECK POWER SUPPLY CIRCUIT
1.Turn the ignition switch OFF.
2.Disconnect IPDM E/R connectors.
3.Check voltage between IPDM E/R harness connectors and the ground.
Is the measurement value normal?
YES- GO TO 3.
NO- Repair the harness or connector.
3. CHECK GROUND CIRCUIT
Check continuity between IPDM E/R harness connectors and the ground.
Does continuity exist?
YES- INSPECTION END