Release Valve
Release Valve Check:
1. Measure resistance between terminals. It should be 25 - 30 ohms
2. With no power applied, check air flow through valve from actuator side as described on image chart.
3. Apply 12V across valve terminals and check air flow through valve from actuator side as described on image chart.
4. If not as specified, replace valve.