Exhaust Gas Sensor Heater Control
1986-88 300ZX
The ECU turns on the exhaust gas heater when engine speed is less than 3200 RPM on 1986-87 non-turbo engines or 2800 RPM on 1988 non-turbo engines and all turbo engines. The exhaust gas heater also comes on when engine is not under a heavy load.