Display Check
Trip Reset Switch:
1. While depressing reset switch A, turn ignition switch ON.
NOTE: Reset switch A should remain depressed until self check operation begins.
2. Segments for meters and gauges should illuminate one after another.
3. If any particular segment remains off, replace combination meter.