Neutral Safety Switch: Adjustments
Inhibitor Switch Adjustment1. Remove control cable from manual shaft.
2. Set manual shaft in 'N" position.
3. Loosen inhibitor switch fixing bolts.
4. insert pin into adjustment holes in both inhibitor switch and manual shaft as near vertical as possible.
5. Reinstall any part removed.
6. Check continuity of inhibitor switch. - Refer to "Electrical Components Inspection". Testing and Inspection