Oxygen Sensor: Service and Repair
Oxygen Sensor:
REMOVAL
1. Disconnect harness terminal.
2. Remove sensor with suitable socket or wrench.
INSTALLATION
1. Apply a thin coating of anti-seize compound to the threads.
NOTE: Do not contaminate sensing tip with compound.
2. Install sensor and torque it to Approx. 18 - 24 N-m (1.8 - 2.4 kg-m, 13 - 17 lb.ft.).
3. Apply a thin coating of dielectric compound to the connector.
4. Connect harness terminal.