Refrigerant Recovery
WARNING:- Discharge only into your recycling equipment.
- Do not release refrigerant into the air.
- Use only authorized refillable refrigerant tanks for your recycling equipment.
- Use of other tanks could cause personal injury.
Refrigerant Tank:
1. Connect vacuum hose to refrigerant recycling equipment and open additional valve and adapter valves.
Refrigerant Tank:
2. Open both valves of manifold gauge set. Make certain refrigerant tank "Gas" and "Liquid" valves are open.
3. Plug unit's power cord into a suitable AC outlet and turn on "Main Power" switch.
4. Turn on "Recovery" switch.
5. Depress "Start" switch. Compressor will start. Compressor will shut off automatically when recovery is complete. Watch for pressure rise to above 0 kPa (0 kg/cm2, 0 psi) within two minutes. If this occurs, repeat this step.
Refrigerant Tank:
6. To drain A/C system oil accumulator, open "Accumulator Pressurizing" valve for approximately 15 seconds to allow some compressor discharge pressure back into accumulator. Close "Accumulator Pressurizing" valve and open "Oi1 Drain" valve slowly and drain accumulator. Do not allow accumulator to completely depressurize. When oil stops draining, close "Oil Drain" valve. Be sure to replace oil in A/C system before servicing.
7. Turn off "Recovery" switch.
8. When recovery tank is full, trip switch at the bottom of weight platform will de-energize compressor and "Tank Full" light will come on. Recycle refrigerant in tank before removing.