Neutral Safety Switch: Testing and Inspection
Shift Linkage Connection To Inhibitor Switch:
1. Disconnect control cable from manual shaft.
Inhibitor Switch Positions:
Inhibitor Position Chart:
Testing Switch:
2. Check continuity between terminals 1 and 3 and between terminals 4 and 2, 5, 6, 7, 8, 9 while moving selector lever through each position.
3 If N.G. on step 2, adjust manual control linkage.
4. Check continuity of inhibitor switch terminal. - Refer to step 1.
Replacing Switch:
5. If N.G. on step 4, replace inhibitor switch.