Inhibitor Switch
INHIBITOR SWITCH- Check continuity in "N", "P" and "R" positions.
- With manual shaft held in "N" position, turn manual shaft an equal amount in both directions to see if current flow positions are nearly the same. (When manual lever is in each position, continuity normally exists within 1.5 ° in either direction.) If current flows outside normal position, or if normal flow position is out of specifications, properly adjust inhibitor switch.