Fuel Pump Relay: Testing and Inspection
Fuel Pump Relay:
Check continuity between terminals 3 and 5:
- With 12 Volts DC supply between
terminals 1 and 2 Continuity
- With No 12 Volt DC supply between
terminals 1 and 2 NO Continuity