Neutral Safety Switch: Testing and Inspection
Inhibitor Switch Test:
Test Chart:
1. Check continuity between terminals 1 and 2 and between terminals 3 and 4, 5, 6, 7, 8, 9 while moving selector lever through each position.
Inhibitor Switch Control Cable:
2 If N.G, check again with control cable disconnected from manual shaft of A/T assembly. - Refer to step 1.
3 If OK on step 2, adjust control cable.
Inhibitor Switch Testing:
4. If N.G. On step 2, Remove inhibitor switch from A/T and check continuity of inhibitor switch terminal. - Refer to step 1.
Replacing Switch:
5. If OK in step 4, Adjust inhibitor switch.
6. If N.G. on step 4, replace inhibitor switch.