Inhibitor Switch
Fig. 5 Adjusting Inhibitor Switch:
1. Remove control cable from manual shaft.
2. Loosen inhibitor switch attaching screws.
3. Set selector lever manual shaft at Neutral position.
4. Insert suitable pin into adjustment holes in both inhibitor switch and switch lever as near vertical as possible, Fig. 5.
5. Tighten inhibitor switch screws.
6. Connect control cable, the check switch for continuity.