Operation CHARM: Car repair manuals for everyone.

Canister Purge Solenoid

EGR/Canister Control Solenoid Valve
Operating voltage 12 Volts DC
Resistance value 30.0 to 40.0 Ohms @ 25°C (77° F)
12 Volts DC applied to both terminals air flow
12 Volts DC NOT applied to both terminals no air flow

Operating characteristics:
Energized engine temperature below 60° C (140° F)
Energized engine rpm less than 800
Energized engine rpm more than 5200
Energized vehicle speed below 18 km/h (11 m.p.h.)