Control Valve Assembly and Accumulators Inspection
Control Valve Assembly and Accumulators Inspection1. Drain fluid from drain plug.
2. Remove oil pan and gasket.
3. Remove oil strainer.
Bolt Length And Location:
4. Remove control valve assembly by removing fixing bolts and disconnecting harness connector.
5. Remove solenoids and valves from valve body it necessary.
6. Remove terminal cord assembly if necessary.
7. Remove accumulator A, B, C and D by applying compressed air if necessary.
- Hold each piston with rag.
8. Reinstall any part removed.
- Always use new sealing parts.