Inhibitor Switch Adjustment
1. Remove manual control linkage from manual shaft of A/T assembly.
2. Set manual shaft of A/T assembly in "N" position.
3. Loosen inhibitor switch fixing bolts.
4. Use a 4 mm (0.16 in) pin for this adjustment.
a. Insert the pin straight into the manual shaft adjustment hole.
b. Rotate inhibitor switch until the pin can also be inserted straight into hole in inhibitor switch.
5. Reinstall any part removed.
6. Check continuity of inhibitor switch.