CONSULT Setting Procedure
3.CRUISE TEST
^ Check all items listed in Parts 1 through 3.
With CONSULT
^ Using CONSULT, conduct a cruise test and record result.
^ Print the result and ensure that shifts and lock-ups take place as per "Shift Schedule".
CONSULT Setting Procedure
1. Turn off ignition switch.
2. Connect "CONSULT" to Data link connector for CONSULT
3. Turn on ignition switch.
4. Touch "START".
5. Touch "A/T".
6. Touch "DATA MONITOR".
7. Touch "SETTING" to set recording condition.
8. Touch "LONG TIME" and "ENTER" key.
9. Go back to SELECT MONITOR ITEM and touch SIGNALS".
10. Touch "START".
11. When performing cruise test, touch "RECORD".
12. After finishing cruise test part 1, touch "STOP".
13. Touch "DISPLAY".
14. Touch "PRINT".
15. Touch "PRINT" again.
16. Check the monitor data printed out.
17. Continue cruise test part 2 and 3.