Operation CHARM: Car repair manuals for everyone.

IACV-FICD Solenoid Valve




COMPONENT DESCRIPTION
The IACV-FICD solenoid valve is built into the IACV-AAC valve body. When the air conditioner is on, the IACV-FICD solenoid valve supplies additional air to adjust to the increased load.







DIAGNOSTIC PROCEDURE

COMPONENT INSPECTION
IACV-FICD solenoid valve

1. Disconnect IACV-FICD solenoid valve harness connector.




2. Check resistance between terminals (1) and (5).

Resistance: 75 - 125 Ohms at 25°C (77°F)

If NG, replace the solenoid valve.




WIRING DIAGRAM