IACV-FICD Solenoid Valve
COMPONENT DESCRIPTION
The IACV-FICD solenoid valve is built into the IACV-AAC valve body. When the air conditioner is on, the IACV-FICD solenoid valve supplies additional air to adjust to the increased load.
DIAGNOSTIC PROCEDURE
COMPONENT INSPECTION
IACV-FICD solenoid valve
1. Disconnect IACV-FICD solenoid valve harness connector.
2. Check resistance between terminals (1) and (5).
Resistance: 75 - 125 Ohms at 25°C (77°F)
If NG, replace the solenoid valve.
WIRING DIAGRAM