Operation CHARM: Car repair manuals for everyone.

Camshaft Position Sensor

Voltage Test Table
Terminal (3) and Ground Approx. 2.7 Volts Alternating Current (VAC)
Note: Average voltage for pulse signal. Actual pulse signal can be confirmed by an oscilloscope.
Terminal (4) and Ground Approx. 2.7 Volts Alternating Current (VAC)
Note: Average voltage for pulse signal. Actual pulse signal can be confirmed by an oscilloscope.