Camshaft Position Sensor
Voltage Test TableTerminal (3) and Ground | Approx. 2.7 Volts Alternating Current (VAC) Note: Average voltage for pulse signal. Actual pulse signal can be confirmed by an oscilloscope. |
Terminal (4) and Ground | Approx. 2.7 Volts Alternating Current (VAC) Note: Average voltage for pulse signal. Actual pulse signal can be confirmed by an oscilloscope. |