Operation CHARM: Car repair manuals for everyone.

Circuit Breaker: Testing and Inspection

Circuit Breaker Inspection:




For example, when current is 30 A , the circuit is broken within 8 to 20 seconds.
Circuit breakers are used in the following systems.
^ Power window & power door lock
^ Power seat

CAUTION:
^ If it becomes necessary to start the engine with a booster battery and jumper cables, use a 12-Volt booster battery.
^ After connecting battery cables, ensure that they are tightly clamped to battery terminals for good contact.
^ Never add distilled water through the hole used to check specific gravity.