Ignition Cable: Testing and Inspection
DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE (Overall)
WITH CONSULT
1) Turn ignition switch "ON", and select "DATA MONITOR" mode with CONSULT.
2) Start engine and warm it up sufficiently.
3) Turn ignition switch "OFF" and wait at least 5 seconds.
4) Start engine again and drive at 1,500 - 4,000 rpm for at least 10 minutes.
OR
WITH GST
1) Start engine and warm it up sufficiently.
2) Turn ignition switch "OFF" and wait at least 5 seconds.
3) Start engine again and drive at 1,500 - 4,000 rpm for at least 10 minutes.
4) Select "MODE 3" with GST.
OR
WITH NO TOOLS
1) Start engine and it warm up sufficiently.
2) Turn ignition switch "OFF" and wait at least 5 seconds.
3) Start engine again and drive at 1,500 - 4,000 rpm for at least 10 minutes.
4) Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.
DIAGNOSTIC PROCEDURE
COMPONENT INSPECTION
Ignition wires
1. Inspect wires for cracks, damage, burned terminals and for improper fit.
2. Measure the resistance of wires to their distributor cap terminal. Move each wire while testing to check for intermittent breaks.
Resistance: 13.6 - 18.4 K Ohms/m (4.15 - 5.61 K Ohms/ft) at 25°C (77°F)
If the resistance exceeds the above specification, inspect ignition wire to distributor cap connection. Clean connection or replace the ignition wire with a new one.