Operation CHARM: Car repair manuals for everyone.

With Consult Scan Tool

The self-diagnosis results can be read by CONSULT, as follows:

1. Connect "CONSULT" to data link connector.

DATA LINK FOR CONSULT:





Data link connector for CONSULT is located in left side of dash panel.





2. Turn ignition switch "ON". (When CONSULT is connected, the "AIR BAG" warning lamp will be changed to diagnosis mode.)
3. Touch "START" to operate "CONSULT".
4. Touch "AIRBAG" to choose air bag system.
5. Touch "SELF DIAG RESULTS" to read self-diagnosis results.

Consult Diagnostic Code Chart:





6. Problem codes are displayed on "SELF DIAG RESULTS".
7. When "PRINT" is pressed, information displayed on "SELF DIAG RESULTS" is printed out.
- While CONSULT is displaying this "SELF-DIAG RESULTS" information, do not disconnect CONSULT from data link connector.
- When finishing diagnosis, make sure to change CONSULT display to SELECT SYSTEM mode by using BACK key.

8. After repairing malfunctioning parts, press "ERASE" to clear self-diagnosis results.
- "ERASE" function requires selecting "ERASE", and completing step 9.

9. Push BACK key of CONSULT until SELECT SYSTEM mode appears to display "SELF-DIAGNOSIS" user mode.
- If malfunctioning parts are not completely repaired, "AIR BAG" warning lamp will blink every 0.5 seconds.

10. Push the power off switch.
11. Turn off ignition switch, disconnect CONSULT.
12. Turn ignition switch "ON".
13. "AIR BAG" warning lamp should come on for about 7 seconds and then go off.