Air Flow Meter/Sensor: Testing and Inspection
COMPONENT INSPECTION1. Turn ignition switch "ON".
2. Start engine and warm it up sufficiently.
3. Check voltage between terminal (1) and ground.
Conditions / Voltage V
Ignition Switch "ON" (Engine stopped.) / Less than 1.0
Idle ( Engine is warmed-up sufficiently.) / 1.3 - 1.7
2,500 rpm / 1.7 - 2.1
Idle is about 4,000 rpm* / 1.3 - 1.7 to Approx. 4.0
* Check for linear voltage rise in response to increase to about 4,000 rpm in engine speed.
4. If NG, remove mass air flow sensor from air duct. Check hot wire for damage or dust.