Charging System: Testing and Inspection
Generator Test: With IC Regulator:
Before conducting a generator test, make sure that the battery is fully charged. A 30-volt voltmeter and suitable test probes are necessary for the test. The generator can be checked easily by referring to the Inspection Table.
Before starting diagnosis, inspect the fusible link.
1) use fully charged battery.
2) Light : charge warning light
G.G.G.: Generator parts except is regulator
IC-RG: IC regulator
O.K.: IC-generator is in good condition.
3) When reaching "Damaged G.C.G.", remove generator from vehicle and disassemble, inspect and correct or replace faulty parts.
4) *Method of grounding F terminal (HITACHI make only)
Gasoline Engine Model:
Gasoline engine model
Contact tip of wire with brush and attach wire to generator body.
5) Terminals "S", "L", "B" and "E" are marked on rear cover of generator.