Rear Defogger: Testing and Inspection
Filament Check:
^ When measuring voltage, wrap tin toil around the top of the negative probe. Press the toil against the wire with your finger. Otherwise, the element may be damaged.
Filament Check:
1. Attach probe circuit tester (in volt range) to middle portion of each filament.
Filament Check:
2. If a filament is burned out, circuit tester registers 0 or 12 Volts.
Filament Check:
3. To locate burned out point, move probe along filament. Tester needle swings abruptly at the burned point.