CONSULT Inspection Procedure
Consult Inspection Procedure:
1. Turn "OFF" Ignition switch .
2. Connect "CONSULT" to the data link connector for CONSULT.
Consult Inspection Procedure:
3. Turn "ON" Ignition switch.
4. Turn "ON" ASCD main switch.
5. Touch "START" (on CONSULT display).
6. Touch ASCD
7. Touch SELF-DIAG results.
Consult Inspection Procedure:
^ Self diagnostic results are shown on display.
Consult Inspection Procedure:
8. Touch DATA MONITOR.
Consult Inspection Procedure:
^ Touch "START"
^ Data monitor results are shown on display.