Keyless Entry: Testing and Inspection
Trouble Symptom^ All functions of remote control system do not operate.
^ Some functions of multi-remote controller do not operate.
NOTE:
^ The unlock and panic alarm operation of the multi-remote control system does not activate with the ignition key inserted in the ignition key cylinder.
^ The lock operation of the multi-remote control system does not activate with the key inserted in the ignition key cylinder.
Diagnostic Procedure 1
Check remote controller battery.
NOTE: Remote controller does not function if battery is not set correctly.
Diagnostic Procedure 2
All remote controls do not function even if remote controller is operated properly.
Diagnostic Procedure 3
Interior lamp does not turn on for 30 seconds when pressing unlock button of remote controller. Everything else functions.
Diagnostic Procedure 4
Hazard indicator does not flash twice when pressing lock button of remote controller. Everything else functions.
ID Code Entry Procedure
Enter the identity (ID) code manually when:
^ remote controller or control unit is replaced.
^ an additional remote controller is activated.
To enter the ID code, follow the procedures below.
NOTE:
^ If you need to activate more than two additional new remote controllers, repeat the procedure "Additional ID code entry" for each new remote controller.
^ If the same ID code that exists in the memory is input, the entry will be ignored.
^ Entry of four ID codes maximum is allowed and any attempt to enter more will be ignored.
^ Any ID codes entered after termination of the "setting mode" will not be accepted. Additional remote control signals will be inhibited if not entered during the "setting" mode.