Multi-Remote Control System
INPUTSPower is supplied at all times
^ through 10 A fuse (No. (6) , located in the fuse block).
^ to key switch terminal (1)
When the key switch is ON (key is inserted in ignition key cylinder), power is supplied
^ through key switch terminal (2)
^ to smart entrance control unit terminal (24)
When the door switch LH is OPEN, ground is supplied
^ to smart entrance control unit terminal (15)
^ through door switch LH terminal (1)
^ to door switch LH terminal (3)
^ through body grounds (B4), (B13) and (T16).
When the door switch RH is OPEN, ground is supplied
^ to smart entrance control unit terminal (16)
^ through door switch RH body ground.
When the door lock actuator LH (door unlock sensor) is UNLOCKED, ground is supplied
^ to smart entrance control unit terminal (12)
^ through door lock actuator LH (door unlock sensor) terminal (4)
^ to door lock actuator LH (door unlock sensor) terminal (2)
^ through body grounds (M5) and (M57).
When the door lock actuator RH (door unlock sensor) is UNLOCKED, ground is supplied
^ to smart entrance control unit terminal (13)
^ through door lock actuator RH (door unlock sensor) terminal (4)
^ to door lock actuator RH (door unlock sensor) terminal (2)
^ through body grounds (M5) and (M57).
Remote controller signal input
^ through window antenna
^ to smart entrance control unit terminal (37).
The multi-remote control system controls operation of the
^ power door lock
^ interior lamp
^ panic alarm
^ hazard lamp
^ ID code entry.
OPERATED PROCEDURE
Power door lock operation
When the following input signals are both supplied:
^ key switch OFF (when key is not inserted in ignition key cylinder);
^ door switch CLOSED (when all the doors are closed); smart entrance control unit locks all the doors with input of LOCK signal from remote controller.
Smart entrance control unit unlocks the doors with input of UNLOCK signal from remote controller.
Hazard reminder
Power is supplied at all times
^ through 10 A fuse (No. (5), located in the fuse block)
^ to multi-remote control relays-1 and 2 terminal (1).
When smart entrance control unit receives a LOCK signal, ground is supplied
^ to multi-remote control relays-1 and 2 terminal (2)
^ through smart entrance control unit terminal (7)
Multi-remote control relays are now energized and door lock actuators lock all the doors. (Hazard warning lamps flash twice as a reminder.)
Interior lamp operation
When the following input signals are both supplied:
^ key switch OFF (when key is not inserted in ignition key cylinder);
^ door switch CLOSED (when all the doors are closed);
multi-remote control system turns on interior lamp (for 30 seconds) with input of UNLOCK signal from remote controller.
For detailed description, refer to "Interior, Spot and Trunk Room Lamps".
Panic alarm operation
When key switch is OFF (when key is not inserted in ignition key cylinder), multi-remote control system turns on and off horn and headlamp intermittently with input of PANIC ALARM signal from remote controller. For detailed description, refer to "THEFT WARNING SYSTEM".