Part 9
14. Install inhibitor switch.
a. Check that manual shaft is in "1" position.
b. Temporarily install inhibitor switch on manual shaft.
c. Move manual shaft to "N".
d. Tighten bolts while inserting 4.0 mm (0.157 inch) diameter pin vertically into locating holes in inhibitor switch and manual shaft.
15. Install torque converter.
a. Pour ATF into torque converter.
- Approximately 2 liters (2-1/8 US quart, 1-3/4 Imp quart) of fluid are required for a new torque converter.
- When reusing old torque converter, add the same amount of fluid as was drained.
b. Install torque converter while aligning notches and oil pump.
c. Measure distance A to check that torque converter is in proper position.
Distance "A": 26.0 mm (1.024 inch) or more