Keyless Entry: Testing and Inspection
Trouble Symptom^ All functions of remote control system do not operate
^ Some functions of multi-remote controller do not operate.
NOTE:
^ The unlock and panic alarm operation of the multi-remote control system does not activate with the ignition key inserted in the ignition key cylinder.
^ The lock operation of the multi-remote control system does not activate with the key inserted in the ignition key cylinder and one or more of the front doors are open.
Diagnoses Procedure 1
Check remote controller battery.
NOTE: Remote controller does not function if battery is not set correctly.
Diagnoses Procedure 2
All remote controls do not function even if remote controller is operated properly.
Diagnoses Procedure 3
Diagnostic Procedure 3:
Interior lamp does not turn on for 30 seconds when pressing unlock button of remote controller. Everything else functions.
Diagnostic Procedure 4
Hazard indicator does not flash twice when pressing lock button of remote controller. Everything else functions.
ELECTRICAL COMPONENTS INSPECTION
Door Switches
Check continuity between terminals when door switch is pushed and released.
Door Lock Actuator (Door Unlock Sensor)
Check continuity between terminals when door is locked and unlocked.
Key Switch (Insert)
Check continuity between terminals when key is inserted in ignition key cylinder and key is removed from ignition key cylinder.