Without CONSULT Scan Tool
FUNCTION
^ When a problem occurs in the ABS, the warning lamp on the instrument panel comes on. To start the self-diagnostic results mode, ground the self-diagnostic (check) terminal located on the "Data Link Connector for CONSULT". The location of the malfunction is indicated by the warning lamp flashing on the instrument panel.
SELF-DIAGNOSIS PROCEDURE
Part 1 of 2:
Part 2 of 2:
^ Refer to the Chart for procedure.
HOW TO READ SELF-DIAGNOSIS RESULTS (Malfunction Codes)
^ Determine the code No. by counting the number of times the warning lamp flashes on and off.
^ When several malfunctions occur at one time, up to three code numbers can be stored; the latest malfunction will be indicated first.
^ The indication begins with the start code 12. After that a maximum of three code numbers are shown, with the latest one appearing first. The indication then returns to the start code 12 to repeat (the indication will stay on for a maximum of five minutes).