CONSULT Inspection Procedure
CONSULT INSPECTION PROCEDURE1. Turn ignition switch "OFF".
2. Connect "CONSULT" to the data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "IVMS".
6. Perform each diagnostic item according to the item application chart.
IVMS COMMUNICATION DIAGNOSIS
1. Touch "IVMS COMM DIAGNOSIS" in "IVMS-COMM CHECK".
2. Touch "START".
3. If no failure is detected, inspection is end.
If any problem code is displayed, repair/replace the system according to the IVMS communication diagnosis results.
4. Erase the diagnostic results memory.
a. Turn ignition switch "ON".
b. Touch "IVMS".
c. Touch "IVMS COMM DIAGNOSIS" in "IVMS-COMM CHECK".
d. Touch "START" for "IVMS COMM DIAGNOSIS".
e. Touch "ERASE".
WAKE-UP DIAGNOSIS
1. Touch "WAKE-UP DIAGNOSIS" in "IVMS-COMM CHECK".
2. Touch "START" for "WAKE-UP DIAGNOSIS".
3. After touching "START", turn ON switch designated on CONSULT display within 15 seconds.
4. If no failure is detected, touch "NEXT" and perform wake-up diagnosis for next LCU or touch "END". (INSPECTION END)
If any problem is displayed, replace the LCU.
If "SW DATA UNMATCH" is displayed, touch "RETEST" and perform wake-up diagnosis again.