Procedure 2
Inspecting SRS Malfunctioning Parts By Using CONSULT - Diagnosis ModeData Link Connector:
1. Turn ignition switch "OFF".
2. Connect "CONSULT" to Data link connector.
Diagnostic Procedure 2 (With Consult):
3. Turn ignition switch "ON".
4. Touch "START".
Diagnostic Procedure 2 (With Consult):
5. Touch "AIRBAG".
Diagnostic Procedure 2 (With Consult):
6. Touch "SELF-DIAG [CURRENT]".
Diagnostic Procedure 2 (With Consult):
7. Diagnostic codes are displayed on "SELF-DIAG [CURRENT]".
Diagnostic Procedure 2 (With Consult):
If no self-diagnostic failure is detected on "SELF-DIAG [CURRENT]" even though malfunction is detected in DIAGNOSTIC PROCEDURE 1, Procedure 1check the battery voltage. If the battery voltage is less than 9V, charge the battery. Then go to DIAGNOSTIC PROCEDURE 4 Procedure 4for final checking. If the battery voltage is OK, go to DIAGNOSTIC PROCEDURE 6 Procedure 6 to diagnose the following situations:
- Self-diagnostic failure "SELF-DIAG [PAST]" (previously stored in the memory) might not be erased after repair.
- The SRS system malfunctions intermittently.
8. Touch "PRINT".
9. Compare diagnostic codes to the CONSULT DIAGNOSTIC CODE CHART. Trouble Code Description and Repairs
10. Touch "BACK" key of CONSULT until SELECT SYSTEM appears in order to return to User mode from Diagnosis mode, then turn off CONSULT.
11. Turn ignition switch "OFF", then disconnect CONSULT and both battery cables.
12. Repair the system as outlined by the "Repair order" in CONSULT DIAGNOSTIC CODE CHART, that corresponds to the problem code. Trouble Code Description and Repairs
13. After repairing the system, go to DIAGNOSTIC PROCEDURE 4 Procedure 4for final checking.
Consult Diagnostic Code Chart (Part 1 Of 2):
Consult Diagnostic Code Chart (Part 2 Of 2):
Consult Diagnostic Code Chart ("Self-Diag[Current]")