Hazard Warning Lamps: Description and Operation

Power is supplied at all times to hazard switch terminal (3) through:
^ 10 A fuse [No. 20, located in the fuse block (J/B)].
With the hazard switch in the ON position, power is supplied:
^ through terminal (1) of the hazard switch
^ to combination flasher unit terminal (1)
^ through terminal (3) of the combination flasher unit
^ to hazard switch terminal (4).
Ground is supplied to combination flasher unit terminal (2) through body grounds (M2) and (M61)
Power is supplied through terminal (5) of the hazard switch to:
^ front combination lamp LH terminal (3)
^ combination meter terminal (30)
^ rear combination lamp LH terminal (4).
Power is supplied through terminal (6) of the hazard switch to:
^ front combination lamp RH terminal (3)
^ rear combination lamp RH terminal (4)
^ combination meter terminal (26).
Ground is supplied to terminal (2) of each front combination lamp through body grounds (E10) and (E34).
Ground is supplied to terminal (2) of each rear combination lamp through body grounds (T6) and (T9)
Ground is supplied to combination meter terminal (27) through body grounds (M2) and (M61) With power and ground supplied, the combination flasher unit controls the flashing of the hazard warning lamps.

WITH MULTI-REMOTE CONTROL SYSTEM
Power is supplied at all times:
^ through 10 A fuse [No. 20, located in the fuse block (J/B)]
^ to multi-remote control relay-1 terminals (1), (3) and (6).
Ground is supplied to multi-remote control relay-1 terminal (2), when the multi-remote control system is triggered through the smart entrance control unit.
Refer to "MULTI-REMOTE CONTROL SYSTEM"
When multi-remote control relay-1 is energized.
Power is supplied through terminal (5) of the multi-remote control relay-1:
^ to front combination lamp LH terminal (3)
^ to combination meter terminal (30)
^ to rear combination lamp LH terminal (4).
Power is supplied through terminal (7) of the multi-remote control relay-1:
^ to front combination lamp RH terminal (3)
^ to combination meter terminal (26)
^ to rear combination lamp RH terminal (4).
Ground is supplied to terminal (2) of each front combination lamp through body grounds (E10) and (E34).
Ground is supplied to terminal (2) of each rear combination lamp through body grounds (T6) and (T9)
Ground is supplied to combination meter terminal (27) through body grounds (M2) and (M61).
With power and ground supplied, the smart entrance control unit controls the flashing of the hazard warning lamps.