SERVICE DATA AND SPECIFICATIONS (SDS)

GENERATOR
Type
LR1100-757B
HAP

Nominal rating V-A
12-100

Ground polarity
Negative

Minimum revolution under no-load (When 13.5 volts is applied) rpm
Less than 1,000

Hot output current (When 13.5 volts is applied) A/rpm
More than 24/1,300
More than 71/2,500
More than 98/5,000

Regulated output voltage V
14.1-14.7

Minimum length of brush mm(in)
6.00 (0.236)

Brush spring pressure N (g, oz)
1.000-2.432 (102-250, 3.60-8.82)

Slip ring minimum diameter mm (in)
26.0 (1.024)

Rotor (field coil) resistance Ohms
2.05