Auxiliary Mechanism
AUXILIARY MECHANISM: Temperature setting trimmerThis trimmer compensates for differences between temperature setting (displayed digitally) and temperature felt by driver in a range of ±3°C (±6°F).
Operating procedures for this trimmer are as follows:
Starting with STEP 5 under "Self-diagnostic mode", press (fan up) switch to set air conditioning system in auxiliary mode. Display shows "61" in auxiliary mechanism. It takes approximately 3 seconds. Then, press either (HOT) or (COLD) switch as desired. Temperature will change at a rate of 0.5°C (1°F) each time a switch is pressed.
When battery cable is disconnected, trimmer operation is canceled and temperature set becomes that of initial condition, i.e. 0°C (0°F).