Symptom Related Diagnostic Procedures
CONSULTConsult Inspection Procedure
1. Turn Ignition switch "OFF" .
2. Connect "CONSULT" to the data link connector.
3. Turn Ignition switch "ON" .
4. Touch "START".
5. Touch "IVMS"
6. Touch "POWER WINDOW"
^ DATA MONITOR and ACTIVE TEST are available for the power
On-Board Diagnosis
On-board Diagnosis - Mode IV (Power Window Monitor)
How To Perform Mode IV
Description
In mode IV, driver window is automatically operated. In conjunction with power window motor (DOWN) "ON", indicator lamps (interior lamp and front step lamps) turn on. When power window "lock" is detected, power window motor will stop and the indicator lamps will turn off.
NOTE: As soon as manual switches (each seat's power window switch) turn ON, driver power window motor (DOWN) stops and diagnosis ends.
* While power window motor is being operated, electrical ripple occurs.
Trouble Diagnoses
Work Flow
NOTE:
^ When LCU connectors are disconnected for more than 1 minute such as during trouble diagnosis, the "disconnected" data will be memorized by the BCM. Therefore, after reconnecting the LCU connectors, erase the memory.
^ To erase the memory, perform the procedure below.
Erase the memory with CONSULT or turn the ignition switch to "OFF" position and remove 7.5 A fuse (No. (56) located in the fuse and fusible link box).
Preliminary Check
Symptom Chart
Diagnostic Procedure 1
(Ignition switch ON signal check)
Diagnostic Procedure 2
(Power window lock switch check)
Diagnostic Procedure 3
(Power window main switch)
Diagnostic Procedure 4
(Power window sub-switch (Passenger side, Rear LH, RH check)
Diagnostic Procedure 5
(Power window regulator check)
Diagnostic Procedure 6
(Power window automatic switch check)