Operation CHARM: Car repair manuals for everyone.

Clearance Specifications

Whenever valve clearances are adjusted to cold specifications, check that the clearances satisfy hot specifications and adjust again if necessary
Intake For Adjusting Hot 0.32 - 0.40 Millimeter (mm)
Cold
At a temperature of approximately 20 deg C
0.25 - 0.33 Millimeter (mm)
For Checking Hot 0.21 - 0.49 Millimeter (mm)
Exhaust For Adjusting Hot 0.37 - 0.45 Millimeter (mm)
Cold
At a temperature of approximately 20 deg C
0.32 - 0.40 Millimeter (mm)
For Checking Hot 0.30 - 0.58 Millimeter (mm)
Stem To Guide Clearance Intake 0.020 - 0.050 Millimeter (mm)