IACV-FICD Solenoid Valve
EC-FICD-01:
EC-FICD-01 - Connector View:
WIRING DIAGRAM
M8, E65:
F30, F32, M33:
COMPONENT DESCRIPTION
When the air conditioner is on, the IACV-FICD solenoid valve supplies additional air to adjust to the increased load.
ECM TERMINALS AND REFERENCE VALUE
Specification data are reference values and are measured between each terminal and (43) (ECM ground).
Diagnostic Procedure (Part 1 Of 2):
Diagnostic Procedure (Part 2 Of 2):
DIAGNOSTIC PROCEDURE
COMPONENT INSPECTION
IACV-FICD solenoid valve
Disconnect IACV-FICD solenoid valve harness connector.
- Check for clicking sound when applying 12V direct current to terminals.
- Check plunger for seizing or sticking.
- Check for broken spring.