Tools - Consult Lithium Backup Battery Replacement
Classification:GI91-004
Reference:
NTB91-046
Date:
May 9, 1991
CONSULT LITHIUM BATTERY REPLACEMENT
Applied Vehicle(s):
All models
SERVICE INFORMATION
Your CONSULT unit incorporates two batteries:
^ One is a NiCad rechargeable battery which powers the display and the printer.
^ The other is a lithium battery to backup the memory, clock, and calendar functions when the NiCad battery has been removed or is completely discharged.
The lithium battery must be replaced once it is discharged. IT IS VERY IMPORTANT THAT THIS BATTERY BE REPLACED ONLY WITH A SANYO ELECTRIC CO. LTD., CR2032 BATTERY. Replacement batteries may be purchased locally. The replacement procedure is shown below.
CAUTION:
Use of another battery may create the risk of fire or explosion.
SERVICE PROCEDURE
Replacing The Lithium Battery:
1. Press the power OFF switch.
2. Remove the two card reader screws with a phillips screwdriver. Then remove the card reader as shown in the illustration. It is not necessary to disconnect the connector between the card reader and body.
1. Remove the screw on the lithium battery compartment cover with a phillips screwdriver. Then remove the cover by pushing it in the direction of the arrow.
4. Remove the lithium battery.
5. Insert the new lithium battery with the plus and minus terminals correctly positioned. Then press the lithium battery down and replace the battery compartment cover.
6. Press the power OFF switch and reinstall the program card reader.