ID Code Entry Procedure
REMOTE CONTROLLER ID SET UP WITH CONSULT-IINOTE: If a remote controller is lost, the ID code of the lost remote controller must be erased to prevent unauthorized use. When the ID code of a lost remote controller is not known, all controller ID codes should be erased. After all ID codes are erased, the ID codes of all remaining and/or new remote controllers must be re-registered.
1. Turn ignition switch "OFF".
2. Connect "CONSULT" to the data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "SMART ENTRANCE".
6. Touch "MULTI REMOTE ENT".
7. Touch "WORK SUPPORT".
8. The items are shown on the figure at left can be set up.
- "REMO CONT ID CONFIR"
Use this mode to confirm if a remote controller ID code is registered or not.
- "REMO CONT ID REGIST"
Use this mode to register a remote controller ID code.
NOTE:
Register the ID code when remote controller or smart entrance control unit is replaced, or when additional remote controller is required.
- "REMO CONT ID ERASUR"
Use this mode to erase a remote controller ID code.
- "HZRD REM SET"
Use this mode to activate or deactivate the hazard and horn reminder.
REMOTE CONTROLLER ID SET UP WITHOUT CONSULT-II
NOTE:
- If a remote controller is lost, the ID code of the lost remote controller must be erased to prevent unauthorized use. A specific ID code can be erased with CONSULT. However, when the ID code of a lost remote controller is not known, all controller ID codes should be erased. After all ID codes are erased, the ID codes of all remaining and/or new remote controllers must be re-registered.
To erase all ID codes in memory, register one ID code (remote controller) four times. After all ID codes are erased, the ID codes of all remaining and/or new remote controllers must be re-registered.
- When registering an additional remote controller, the existing ID codes in memory may or may not be erased. If four ID codes are stored in memory, when an additional code is registered, only the oldest code is erased. If less than four ID codes are stored in memory, when an additional ID code is registered, the new ID code is added and no ID codes are erased.
- If you need to activate more than two additional new remote controllers, repeat the procedure "Additional ID code entry" for each new remote controller.
- Entry of maximum four ID codes is allowed. When more than four ID codes are entered, the oldest ID code will be erased.
- Even if same ID code that is already in the memory is input, the same ID code can be entered. The code is counted as an additional code.