Batt/Fluid Temp (Fluid Temp Sens. Circuit & TCM Pwr. Source)
DescriptionThe A/T fluid temperature sensor detects the A/T fluid temperature and sends a signal to the TCM.
CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE
TCM TERMINALS AND REFERENCE VALUE
ON BOARD DIAGNOSIS LOGIC
Diagnostic trouble code BATT/FLUID TEMP SEN with CONSULT-II or 8th judgment flicker without CONSULT-II is detected when TCM receives an excessively low or high voltage from the sensor.
POSSIBLE CAUSE
Check the following items.
- Harness or connectors
(The sensor circuit is open or shorted.)
- A/T fluid temperature sensor
DIAGNOSTIC TROUBLE CODE (DTC) CONFIRMATION PROCEDURE
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-II
1. Start engine.
2. Select "DATA MONITOR" mode for "A/T" with CONSULT-II.
3. Drive vehicle under the following conditions:
Selector lever in D, vehicle speed higher than 20 km/h (12 MPH).
WITHOUT CONSULT-II
1. Start engine.
2. Drive vehicle under the following conditions:
Selector lever in D, vehicle speed higher than 20 km/h (12 MPH).
3. Perform self-diagnosis.
Refer to TCM SELF-DIAGNOSTIC PROCEDURE (NO TOOLS).
WIRING DIAGRAM - AT - BA/FTS
Diagnostic Procedure
1: CHECK INPUT SIGNAL OF A/T FLUID TEMPERATURE SENSOR (WITH CONSULT-II)
2: DETECT MALFUNCTIONING ITEM
3: CHECK TCM POWER SOURCE STEP 1
4: CHECK TCM POWER SOURCE STEP 2
5: DETECT MALFUNCTIONING ITEM
6: CHECK A/T FLUID TEMPERATURE SENSOR WITH TERMINAL CORD ASSEMBLY
7: DETECT MALFUNCTIONING ITEM
8: CHECK INPUT SIGNAL OF A/T FLUID TEMPERATURE SENSOR (WITHOUT CONSULT-II)
9: DETECT MALFUNCTIONING ITEM
10: CHECK DTC
11: CHECK TCM INSPECTION