Trouble Diagnosis Summary of Multi-Remote Control System

ALL FUNCTION OF MULTI-REMOTE CONTROL SYSTEM DO NOT OPERATE

System Description
Remote controller signal is inputted to smart entrance control unit. (The antenna of the system is combined with smart entrance control unit.)
The multi-remote control system controls operation of the power door lock, interior lamp, panic alarm, trunk lid opener and hazard and horn reminder.
Smart entrance control unit receives a LOCK signal from remote controller. Smart entrance control unit locks all doors with input of LOCK signal from remote controller. When an UNLOCK signal is sent from remote controller once, driver's door will be unlocked.
Then, if an UNLOCK signal is sent from remote controller again within five seconds, all other doors will be unlocked.
When smart entrance control unit receives LOCK or UNLOCK signal from remote controller with all doors closed, hazard warning lamp flashes and horn sounds as a reminder. (Horn can be activated or deactivated.) When interior lamp switch is set to DOOR position, all doors are closed and driver's door is locked; multi-remote control system turns on interior lamp for 30 seconds with input of UNLOCK signal from remote controller.
When ignition key is not inserted into key cylinder, multi-remote control system turns on and off horn and headlamp intermittently with input of PANIC ALARM signal from remote controller.
The alarm automatically turns off after 25 seconds or when smart entrance control unit receives any signal from remote controller.
When a TRUNK OPEN signal is sent from remote controller, trunk lid opener actuator opens trunk lid.

Possible Cause
- Remote controller battery
- Remote controller
- Circuit open or short

Diagnostic Repair Procedure (for confirmed incidents)
1. Check remote controller battery: Proper installation and voltage spec = 3 Vor more.
2. Check remote controller function: Use CONSULT-II DATA MONITOR in MULTI-REMOTE ENT to confirm each signal of the remote controller. See illustration.




a. Replace remote controller.
3. Check power supply to smart entrance control unit.
4. Check ground circuit for the smart entrance control unit.

NEW ID OF REMOTE CONTROLLER CANNOT BE ENTERED

System Description
A maximum four ID codes are allowed. When more than four ID codes are entered, the oldest ID code will be erased.
Even if the same ID code that is already in the memory is input, the same ID code can be entered. The code is counted as an additional code.

Possible Cause
- Remote controller battery
- Key switch
- Door switch
- Door lock/unlock switch LH
- Circuit open or short
- Remote controller

Diagnostic Repair Procedure (for confirmed incidents)
1. Check remote controller battery: Proper installation and voltage spec = 3 V or more.

2. Check remote controller function: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm each signal in the remote controller. See illustration.




a. Replace remote controller.
3. Check power supply to smart entrance control unit.
4. Check ground circuit to smart entrance control unit.
5. Check ACC signal to smart entrance control unit.
6. Check key switch input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that KEY ON SW indicates ON when key is inserted into ignition key cylinder. Confirm OFF when key is removed from ignition key cylinder.
a. Check power supply to the key switch.
b. Check circuit between the key switch and smart entrance control unit: Continuity/No shorts to ground.
c. Key switch component test: Continuity should exist when the key is inserted; no continuity with the key removed.
7. Check door switch input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that DOOR SW-ALL indicates ON when any door is open. Confirm OFF when all doors are closed.
a. Check circuit between smart entrance control unit and door switch: Continuity/No shorts to ground.
b. Check circuit between door switch and ground: Continuity.
c. Door component test: Continuity should exist when the switch is in the released (open) position; no continuity in the depressed (closed) position.

8. Check door lock/unlock switch input signal circuit: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that LOCK SW DR/AS indicates ON when lock/unlock switch is turned to LOCK. Confirm that UNLK SW DR/AS indicates ON when lock/unlock switch is turned to UNLOCK.
a. Check circuit between smart entrance control unit and door lock/unlock switch: Continuity/No shorts to ground.
b. Check circuit between door lock/unlock switch and ground: Continuity.




c. Door lock/unlock switch component test:
Check continuity between door lock/unlock switch terminals. See illustration.

POWER DOOR LOCK DOES NOT OPERATE WITH REMOTE CONTROLLER

System Description
Remote controller signal is inputted to smart entrance control unit. (The antenna of the system is combined with smart entrance control unit.)
The multi-remote control system controls operation of the power door lock, interior lamp, panic alarm, trunk lid opener and hazard and horn reminder.
Smart entrance control unit receives a LOCK signal from remote controller. Smart entrance control unit locks all doors with input of LOCK signal from remote controller. When an UNLOCK signal is sent from remote controller once, driver's door will be unlocked.
Then, if an UNLOCK signal is sent from remote controller again within five seconds, all other doors will be unlocked.

Possible Cause
- Remote controller battery
- Remote controller
- Circuit open or short

Diagnostic Repair Procedure (for confirmed incidents)
1. Check power door lock operation: Confirm that power door lock operates manually.
2. Check remote controller battery: Proper installation and voltage spec = 3V or more.
3. Check power supply to smart entrance control unit.
4. Check ground circuit for the smart entrance control unit.
5. Check remote controller function: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that LK BUTTON/SIG ON indicates ON when LOCK button is pushed. Confirm UN BUTTON/SIG ON indicates ON when UNLOCK button is pushed.
a. Replace remote controller.

HAZARD AND HORN REMINDER DOES NOT ACTIVATE PROPERLY WHEN PRESSING LOCK OR UNLOCK BUTTON OF REMOTE CONTROLLER, ALL OTHER FUNCTIONS ARE OK

System Description
Remote controller signal is inputted to smart entrance control unit. (The antenna of the system is combined with smart entrance control unit.)
The multi-remote control system controls operation of the power door lock, interior lamp, panic alarm, trunk lid opener and hazard and horn reminder.
When smart entrance control unit receives LOCK or UNLOCK signal from remote controller with all doors closed, hazard warning lamp flashes and horn sounds as a reminder. (Horn can be activated or deactivated.) If one or more doors are open, the hazard and horn reminder will not operate.
The hazard and horn reminder has C mode (horn can be activated) and S mode (horn cannot be activated). Hazard and horn reminder mode can be changed using CONSULT-II WORK SUPPORT mode.

Possible Cause
- Circuit open or short
- Multi-remote control relay
- Door switch
- Remote controller

Diagnostic Repair Procedure (for confirmed incidents)
1. Check remote controller function: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that LK/UN BTN ON indicates ON when LOCK and UNLOCK buttons are pushed at the same time. Confirm OFF when the other buttons are pushed.
a. Replace remote controller.
2. Check whether hazard indicator flashes with hazard switch ON.
3. Check hazard reminder operation: Perform CONSULT-II ACTIVE TEST in MULTI REMOTE ENT. Confirm that hazard indicator illuminates when HAZARD is ON.
a. Check power supply to multi-remote control relay.
b. Check circuit between multi-remote control relay and smart entrance control unit: Continuity/No shorts to ground.
c. Check multi-remote control relay component test.
d. Check circuits between multi-remote control relay and turn signal lamps.
4. Check whether horn sounds with horn switch ON.
5. Check horn reminder setting. (Horn reminder can be activated or deactivated.)
6. Check horn reminder operation: Perform CONSULT-II ACTIVE TEST in MULTI REMOTE ENT. Confirm that horn operates when MULTI REM HRN is ON.
a. Check circuit between horn relay and smart entrance control unit.
7. Check door switch input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that DOOR SW-ALL indicates ON when any doors are open. Confirm OFF when all doors are closed.
a. Check circuit between smart entrance control unit and door switch: Continuity/No shorts to ground.
b. Check circuit between door switch and ground: Continuity.
c. Door component test: Continuity should exist when the switch is in the released (open) position; no continuity in the depressed (closed) position.

INTERIOR LAMP AND KEY HOLE ILLUMINATION OPERATION DOES NOT ACTIVATE PROPERLY

System Description
Remote controller signal is inputted to smart entrance control unit. (The antenna of the system is combined with smart entrance control unit.)
The multi-remote control system controls operation of the power door lock, interior lamp, panic alarm, trunk lid opener and hazard and horn reminder.
When interior lamp switch is set to DOOR position, all doors are closed and driver's door is looked; multi-remote control system turns on interior lamp and key hole illuminates for 30 seconds with input of UNLOCK signal from remote controller.

Possible Cause
- Interior lamp switch
- Door switch
- Front LH door unlock sensor
- Circuit open or short
- Smart entrance control unit

Diagnostic Repair Procedure (for confirmed incidents)
1. Check interior lamp operation by interior lamp switch operation.
2. Check interior lamp switch position.
3. Check interior lamp operation with CONSULT-II: Use CONSULT-II ACTIVE TEST in MULTI REMOTE ENT. Confirm interior lamp illuminates when INT/IGN ILLUM is ON.
a. Check circuit between interior lamp and smart entrance control unit: Continuity/No shorts to ground.
4. Check key hole illumination operation: Use CONSULT-II ACTIVE TEST in MULTI REMOTE ENT. Confirm key hole illumination illuminates when INT/IGN ILLUM is ON.
a. Check key hole illumination.
b. Check circuit between key hole illumination and smart entrance control unit: Continuity/No shorts to ground.
5. Check door switch input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that DOOR SW-ALL indicates ON when any door is open. Confirm OFF when all doors are closed.
a. Check circuit between smart entrance control unit and door switch: Continuity/No shorts to ground.
b. Check circuit between door switch and ground: Continuity.
c. Door component test: Continuity should exist when the switch is in the released (open) position; no continuity in the depressed (closed) position.
6. Check front LH door unlock sensor input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that LOCK SIG DR indicates OFF when front LH door is locked. Confirm ON when front LH door is unlocked.
a. Check circuit between smart entrance control unit and front LH door unlock sensor: Continuity/No shorts to ground.
b. Check circuit between front LH door unlock sensor and ground: Continuity.
c. Front LH door unlock sensor component test: Continuity should exist when the sensor is in the unlock position; no continuity in the lock position.

PANIC ALARM DOES NOT ACTIVATE, BUT ALL OTHER FUNCTIONS ARE OK

System Description
Remote controller signal is inputted to smart entrance control unit. (The antenna of the system is combined with smart entrance control unit.)
The multi-remote control system controls operation of the power door lock, interior lamp, panic alarm, trunk lid opener and hazard and horn reminder.
When ignition key is not inserted in key cylinder, multi-remote control system turns on and off horn and headlamp intermittently with input of PANIC ALARM signal from remote controller.
The alarm automatically turns off after 25 seconds or when smart entrance control unit receives any signal from remote controller.

Possible Cause
- Remote controller
- Theft warning system
- Key switch
- Circuit open short

Diagnostic Repair Procedure (for confirmed incidents)
1. Check remote controller function: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that PANIC BTN indicates ON when PANIC button is pushed. Confirm OFF when the other buttons are pushed.
a. Replace remote controller.
2. Check theft warning operation: Open the front window. Close all doors and lock doors with remote controller.
Wait till security lamp begins to flash every 2.6 seconds, then open any door. The theft warning horns should sound and the headlamps should flash.
3. Check key switch input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that KEY ON SW indicates ON when key is inserted into ignition key cylinder. Confirm OFF when key is removed from ignition key cylinder.
a. Check power supply to the key switch.
b. Check circuit between the key switch and smart entrance control unit: Continuity/No shorts to ground.
c. Key switch component test: Continuity should exist when the key is inserted; no continuity with the key removed.

TRUNK LID DOES NOT OPEN WHEN TRUNK OPENER BUTTON IS PRESSED, BUT ALL OTHER FUNCTIONS ARE OK

System Description
Remote controller signal is inputted to smart entrance control unit. (The antenna of the system is combined with smart entrance control unit.) The multi-remote control system controls operation of the power door lock, interior lamp, panic alarm, trunk lid opener and hazard and horn reminder.
When ignition key is not inserted in key cylinder and a TRUNK OPEN signal is sent from remote controller, trunk lid opener actuator opens trunk lid.

Possible Cause
- Trunk lid opener actuator
- Key switch
- Circuit open or short
- Remote controller

Diagnostic Repair Procedure (for confirmed incidents)
1. Check remote controller function: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that TRUNK BTN/SIG indicates ON when TRUNK button is pushed. Confirm OFF when the other buttons are pushed.
a. Replace remote controller.
2. Check trunk lid opener cancel lever position.
3. Check trunk lid opener operation with trunk lid opener switch.
a. Trunk lid opener actuator component test: Trunk lid opener actuator should operate when battery voltage is applied to trunk lid opener actuator.
4. Check trunk lid opener actuator operation: Perform CONSULT-II ACTIVE TEST in MULTI REMOTE ENT. Confirm that trunk lid opener operates when TRUNK OUTPUT is ON.
a. Check circuit between trunk lid opener actuator and smart entrance control unit.
5. Check key switch input signal: Use CONSULT-II DATA MONITOR in MULTI REMOTE ENT to confirm that KEY ON SW indicates ON when key is inserted into ignition key cylinder. Confirm OFF when key is removed from ignition key cylinder.
a. Check power supply to the key switch.
b. Check circuit between the key switch and smart entrance control unit: Continuity/No shorts to ground.
c. Key switch component test: Continuity should exist when the key is inserted; no continuity with the key removed.