Diagnostic Procedure 3
Diagnostic Procedure 3Final checking after repairing SRS by using CONSULT-II - Diagnosis mode
1. After repairing SRS, connect both battery cables.
2. Connect CONSULT-II to data link connector.
3. Turn ignition switch "ON ".
4. Touch "START".
5. Touch "AIR BAG".
6. Touch "SELF-DIAG [CURRENT]".
7. If no malfunction is detected on "SELF-DIAG [CURRENT]", repair of SRS is completed. Go to step 8.
If any malfunction is detected on "SELF-DIAG [CURRENT]", the malfunctioning part is not repaired completely or another malfunctioning part is detected. Go to "DIAGNOSTIC PROCEDURE 2" and repair malfunctioning part completely. Diagnostic Procedure 2
8. Touch "ERASE".
NOTE: Touch "ERASE" to clear the memory of the malfunction ("SELF-DIAG [PAST]").
If the memory of the malfunction in "SELF-DIAG [PAST]" is not erased, the User mode shows the system malfunction by the operation of the warning lamp even if the malfunction is repaired completely.
9. Touch "BACK" key of CONSULT-II to "SELECT DIAG MODE" screen. Touch "SELF-DIAG [PAST]".
10. Check that no malfunction is detected on "SELF-DIAG [PAST]".
11. Touch "BACK" key of CONSULT-II until "SELECT SYSTEM" appears in order to return to User mode from Diagnosis mode.
12. Turn ignition switch "OFF " then turn off and disconnect CONSULT-II.
13. Go to "Checking SRS Operation by Using "AIR BAG" Warning Lamp with User Mode".